* Estimated delivery times start from the date of shipment, excluding processing time.
* Actual delivery times may vary due to holidays, weather conditions, or customs delays.
Barkirina standard a belaş ji bo fermanên zêdetir ji $9.9
Polîtîkaya vegerê
Tiştên vegerê dê di nav 40 rojan de were qebûl kirin dema ku roja wergirtina malê ye. Tiştên xweser nayên vegerandin an guhertin. Tiştên ku bi karta diyariya elektronîkî hatine kirin tenê dikarin were guhertin; veger nayê sepandin.
Diyariya belaş
Bi xêr hatî Roymall, malpera weya pîşeyî ji bo kirîna diyariyên depoya departmanê ya premium. Em piştgirî û qedirgirîya we bilind dikin û em dixwazin spasiya xwe bi zêdekirina hêvîya kêfê ya kirînên we nîşan bidin. Dema ku hûn li vir dikirin, hûn ne tenê hilberên kalîteya bilind ên ku jiyana we baştir dikin bistînin, lê hûn ê diyariyek belaş a taybetî jî bi her fermanê bistînin. Amade ne ku koleksiyona me vedikin û diyariyên we yên bêkêmasî bibînin? Di navbijartina me ya hilberên depoya departmanê ya premium bigerin, fermanê bidin û paşê li benda diyariya belaş a we ya bi kirîna we re were.
Polîtîkaya barkirinê
Em ê piştî wergirtina fermanên we ji bo şandina tiştan bi xebatê bigirin û pê ewle bin ku ew bi ewlehî têne. Agahiyên şandinê dê di e-nameya weya pejirandinê de were dayîn.Di piraniya rewşan de, ferman di nav 2 rojan de têne sepandin.Di şert û mercên taybetî de, wê wiha dereng bibin: Dema ku hûn fermanê di şemî, yekşem an jî înên giştî de bidin, dê 2 roj dereng bibin.Normal, ew hewce dike 5-7 rojên kar (ji duşemê heta înê) bêyî ku ji hêla derengiya firînê an faktorên din yên hawîrdorê ve were bandor kirin.Ji ber ku karûbara meya şandinê li seranserê cîhanê ye, ji ber vê yekê dema şandinê dê li gor cihê we be, ji ber vê yekê heke hûn li navçeyên dûr an welatan in, hûn hewce ne ku hinekî bisekinin.
1. Polîtîkaya Vegerê & Guhertinê
Em tenê tiştên ku ji roymall.com hatine kirin qebûl dikin. Heke hûn ji belavkerên me yên herêmî an firoşgehên din bikirin, hûn nikarin wan li vir vegerînin.Tiştên firotanê yên dawî an diyariyên belaş ji bo vegerê nayên qebûl kirin.Ji bo mafdarî ji bo vegerê, tişta we divê nehatiye bikar anîn û di heman rewşê de be ku hûn wê wergirtiye. Divê ew di pakêta xweya orîjînal de jî be.Piştî ku hûn rêwerzên vegerê ji me wergirtin, ji kerema xwe tiştên xwe yên vegerandî pakêj bikin û pakêta xwe li postexaneya herêmî an kuryeyek din bihêlin.Em ê tiştên we yên vegerandî an guhartî di nav 3-5 rojên karkirinê de piştî ku em wê wergirin, bisekinin. Veger dê bixweber li ser rêbaza weya orîjînal a dayînê were kredî kirin.Tiştên ku bi awayekî xweser hatine çêkirin, di nav de mezinahiya xweser, rengê xweser, an çapa xweser, nayên vegerandin an guhertin.Heke hûn hewceyê alîkariyê bin, ji kerema xwe bi me re têkilî daynin. service@roymall.com an Whatsapp: +447549870296
2.Polîtîkaya Vegerê
Hûn ê piştî ku em pakêta vegerandî wergirin û kontrol bikin, vegerê tevahî an 100% krediya dikanê bistînin. Veger dê bixweber li ser rêbaza weya orîjînal a dayînê were kredî kirin.Ji kerema xwe bînin ku lêçûnên barkirinê û her qebzeyek an xerc nayê vegerandin. Lêçûnên zêde yên barkirinê piştî ku pakêt hat şandin, nayê vegerandin. Hûn berpirsiyar in ku hûn van lêçûnan bidin û em nikarin wan bêpar bikin an vegerînin, heta ku ferman ji me re were vegerandin.Heke pirsgirêkek bi prosesa vegerê hebe, ji kerema xwe bi me re têkilî daynin. service@roymall.com an Whatsapp: +447549870296
20A DC Digital Multifunction Power Meter Energy Monitor Module Voltmeter Ammeter 6.5V-100V
Description:
Working Voltage
DC 6.5V-100V
Measuring Voltage
DC 6.5V-100V
Measuring Voltage
0-20A
Rated Power
2000W
Display
LCD
Display Format
Power
0.0-999.9W (<1KW)
1000-2000w(>1KW)
Energy
0-999Wh(<10KWh)
10-9999KWh(>10KWh)
Voltage
6.50-99.99V
Current
0.00-20.00A
Feature: - 20A DC multifunction power meter - LCD display wih backlight, easy to read - Bult-in shunt design, no extra needed - Power, current, voltage and energy display and monitor timely , easy to know electric energy consumption - Electric energy clear function, perfect for various device monitor separately
- Overload alarm function (over power alarm threshold, the backlight and voltage flashing alarm) - Power memory, shave the power parameter when power down, safe to use
Operaqtion Tips:
1. The backlight control
By short press the button to turn on or off the backlight, In the bakclight mode,the data will automatically store when power down
2. The energy cleared
Step 1: Press the power button 5 seconds until the digital display "CLr" , then release the button;
Step 2: Now it is in the "energy clear" mode, press the button again, the energy data is cleared and stop flashing;
Step 3: If in the "energy clear" mode you do not press the button in 5 seconds,then the energy data will not be cleared
3. Set power alarm value
Step 1: Press the button, when the power area display "SET ", release button,
Step 2:it is in the pweor alarming setting mode, the voltage area displays the highest value of the voltage alarm,the current area displays the lowest value of the voltage alarm. Then you can press the button quickly to increase the value" +1", when there is no key operation more than three seconds,
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
It happens that this power meter may give incorrect readings (more than should be). It can be calibrated by opening up the back and shorting the pads marked "W" on the PCB, then add 20V to the input and 1A load (20 Ohms) to the output. Then power on, wait for the display say "Pass" then power off and remove the short. Ta-daa: calibrated.
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
I did a whole bunch of looking around for a supply monitor for my power supply I am building. This one seemed great but the minimum 6.5V input meant I could not supply lower voltages. Upon reading the reviews I found one detailing that removing the diode "D" and placing the power monitor supply positive lead on the cathode (part of the diode with the line on it). allowed for lower voltages to be measured. So I tried it and it worked! Just tweaked the alarm trigger to 0V and now it works great!
Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.
you too??
ordered mine March 10...still nothing as of April 19th.
you too??
ordered mine March 10...still nothing as of April 19th.
Answered by jsdavis55 on 20/04/2019Helpful (0)
0
Q:
Hello, The load part of the device was short-circuited and the shunt resistance between the negative connections inside was burnt. Does any one know the value of this resistance?
Regards //Turkish
Hey, hey,
The load part of the device was short-circuited and the shunt resistance between the internal negative connections burned. Does anyone know the value of this resistance?
Regards
Hello, The load part of the device was short-circuited and the shunt resistance between the negative connections inside was burned. Does anyone know the value of this resistance?
Regards //Türkish
Selam,
Cihazın yük kısmı kısa devre oldu ve içteki negatif bağlantılar arasındaki şönt direnç yandı. Bu direncin değerini bilen var mı?
Saygılar
hellocan you be more specific are you able to provide the R number or part number you are looking to replace, if that is not possible take a photograph of the damaged area and send it to me and I will see what I can do.as follow up if the parts you are refering to are R3
hellocan you be more specific are you able to provide the R number or part number you are looking to replace, if that is not possible take a photograph of the damaged area and send it to me and I will see what I can do.as follow up if the parts you are refering to are R3
Answered by clazh on 24/04/2020Helpful (0)
0
Q:
I bought this , received but want to seek help in connecting it.
I want to monitor a solar panel banks of 48VDC, do i need to get another 12V, input for the meter or what do i need to do to enable me use this meter to monitor the solar panels output volatge of 48VDC
I bought this , received but want to seek help in connecting it.
I want to monitor a solar panel banks of 48VDC, do i need to get another 12V, input for the meter or what do i need to do to enable me use this meter to monitor the solar panels output volatge of 48VDC
can i measure solar power with this i have 1 kva solar panels installed and connected to inverter
so i want to use this meter to connect inbetween solar and inverter to maesure current and voltage?
how
can i measure solar power with this i have 1 kva solar panels installed and connected to inverter
so i want to use this meter to connect inbetween solar and inverter to maesure current and voltage?
how
Hi Vaibhavkumar Birajdar, yes you could use this power meter. But be aware that you stay within it's parameters!...
Hi Vaibhavkumar Birajdar, yes you could use this power meter. But be aware that you stay within it's parameters!...
Answered by armin on 21/11/2019Helpful (0)
0
Q:
In case someone don't know, this instrument can be calibrated for precise measurements. For this, you need a power supply set to 20V and a 20 Ohm resistor connected to the Load terminals. Use thick and short cabling. Remove the back cover, and find the two empty jumper holes in the corner opposite to the connector terminals marked "W". Temporarily short this, then connect the power supply. The display says "CAL" then "PASS", release the power. The instrument is now calibrated. Make a test measurement, correct the voltage if necessary (if after calibration meter shows more than should, raise calibration voltage, calibrate again)
In case someone don't know, this instrument can be calibrated for precise measurements. For this, you need a power supply set to 20V and a 20 Ohm resistor connected to the Load terminals. Use thick and short cabling. Remove the back cover, and find the two empty jumper holes in the corner opposite to the connector terminals marked "W". Temporarily short this, then connect the power supply. The display says "CAL" then "PASS", release the power. The instrument is now calibrated. Make a test measurement, correct the voltage if necessary (if after calibration meter shows more than should, raise calibration voltage, calibrate again)
Common positive, the current measuring shunt is between the negative lines.
Common positive, the current measuring shunt is between the negative lines.
Answered by Aurum on 02/06/2019Helpful (0)
0
Q:
Hello banggod I have bught this meter but i have no idea how to use I want to measure the amount of power from the car headlight bulb How to right way to connect the wire to make it run correct
Hello banggod I have bught this meter but i have no idea how to use I want to measure the amount of power from the car headlight bulb How to right way to connect the wire to make it run correct
This meter only measures up to 100V DC. You could theoretically use a voltage divider circuit to give only 1/3 of your voltage to the meter. It would only show a value up to 100V but you just need to multiply it by 3 to get your total voltage.
This meter only measures up to 100V DC. You could theoretically use a voltage divider circuit to give only 1/3 of your voltage to the meter. It would only show a value up to 100V but you just need to multiply it by 3 to get your total voltage.
Answered by Fluvance on 04/11/2018Helpful (0)